Category Archives: Uncategorized

New blog

I decided during this X-mas holidays to switch back to a self-hosted blog. I started last week with the installation of WordPress on my server in order to replace the outdated web site I had on www.osuna.ch. This page will still be accessible via http://jose.osuna.ch, but I won’t update it anymore.

Please, if you’re still interested in following my posts, visit my new site www.osuna.ch.

Partidos de fútbol a través de Internet

Antes de ayer no echaron el partidazo de la Copa del Rey, Barça-Real 2:2, en ningún canal aquí en la tele. De todas formas, lo pudimos ver a través de Internet. Aunque con muy mala calidad, pero con el comentario original de Canal+. Que, por cierto, me recordaba a los viejos tiempos cuando mi padre escuchaba los partidos en Radio Nacional.

Pués esta vez lo pillé en uno de los portales que te propone www.rojadirecta.me. La dirección que me dio uno de mis alumnos, www.laola1.tv, no funcionaba.

Meinen HP 2500n Color Laserprinter geflickt!

Das war ein Ding! Ich musste den Drucker praktisch ganz auseinandernehmen, um einen Filz zu ersetzen. Aber nun tut der Drucker wieder. Ich k??mpfte mich sch??n durch das Service Manual und entfernte die unten abgebildete Einheit, um darin an den abgenutzten Filz heranzukommen.

Hier die wichtigsten Hinweise (siehe http://www.fixyourownprinter.com/forums/laser/40284#43 zuunterst), die mich auf die Spur brachten, weshalb der Drucker nur noch in Gelb druckte, und die auch den L??sungsansatz gaben:

Re: HP LaserJet 2550n Carousel moves but misaligned by toot (1/3/12 8:19 PM) reply

Hey everybody,

for carousel problem, or toner misaligned be careful to the solenoid on the top of the printer which it used to stop the carousel on the right position.
The solenoid have a "foam" glued on it and with time this foam disappear. so it stay just the glue.
when the solenoid is in action, the solenoid lever glued during very less time on it and make a bad stop of the carousel.

hope this will help you.
sincerely

Re: HP LaserJet 2550n Carousel moves but misaligned by HP-Printer-Dave (1/9/12 11:41 PM) reply

Yes, many HP magnetic clutches are now sticking in the open position too long because the feldt pad for quieting the clutches clicking noise, disintegrates leaving only the glue causing the metal arm to stick to the glue. since these old printers keep going, it is a good idea to either put celophane tape over where the "quieting pad" used to be or remove the clutch arm & scrape off the sticky glue. Now the clutch arm will click when opening but won’t stick open. If taping over the sticky spot, use a 1.5 inch or so strip long enough to go over the brass looking circle that applies the magnitism & also over the back side of the "L" shaped metal. I haven’t had tape fall off in over 5 years. A trick is to tape down a small bit of que-tip cotton where the pad used to be; I have sheets of replacement sticky back feldt I use on all these clutches; I just cut off a small strip for each one. I’ve seen it on the LaserJet 2500, 2550, 2840, 4000, 4050, 4100, 4200, 4, 4+, 5, 5si, 8000, 4500, 4550, etc. If you’r getting the 41.1 error on the 4000 or 4100 then it is probably sticky paper feed clutch arms.

Re: HP LaserJet 2550n Carousel moves but misaligne by dmzcompute (1/10/12 5:17 AM) reply

You need to place something like a felt pad or electrical tape over the area you removed the glue. If you do not then the solenoid L arm will become magnetized causing worse issues. Only seems to be an issue with the 2500 series.

Es ging zwar heute ein halber Tag futsch, geschweige der Aufwand f??r die Internet-Recherche noch vor Weihnachten, aber die Herausforderung ist gemeistert. Und es hat Spass gemacht.

Configuring IIS 6.0 on Windows Server 2003 for Silverlight Applications

From http://learn.iis.net/page.aspx/262/configuring-iis-for-silverlight-applications

1. Go to StartAdministrative Tools and run IIS Manager. See the figure below:

In the application configuration click edit on the .aspx extension and copy the path from the executable textbox. Click the cancel button to close the edit window..

Image007

Now click on the Add button to add a new extension. In the executable textbox paste the path that we just copied from the aspx extension and in the Extension text box enter .wgx (don’t miss the dot before WGX it’s there for a reason). Last uncheck the Verify that file exists check box. And do the same with the Visual WebGui Silverlight extension .swgx (same here the dot is needed).

Image008

If you are asked to apply the extensions on other virtual directories select all and click OK.

Zeitsynchronisation mit Windows Server 2003 DC

Beim Synchronisieren meines Windows 7 Rechners mit dem Domain Controller (Windows Server 2003) kam immer wieder die folgende Fehlermeldung (Ereignisanzeige auf dem Client, System-Protokoll):
Ereignis-ID: 130
Quelle: Time-Service
Vom “NtpClient” konnte kein Domänenpeer als Zeitquelle festgelegt werden, da keine Vertrauensstellung zwischen diesem Computer und der “”-Domäne zur sicheren Zeitsynchronisierung eingerichtet werden konnte. In 3473457 Minuten wird ein weiterer Versuch ausgeführt und das Intervall für weitere Versuche anschließend verdoppelt. Fehler: Die Vertrauensstellung zwischen dieser Arbeitsstation und der primären Domäne konnte nicht hergestellt werden. (0x800706FD)

Auf TechNet wird der Hinweis gemacht, man solle nach Fehlern in der Domänen-Kontroller-Konfiguration achten, ich fand aber keine.

Das Problem konnte ich nun folgendermassen lösen:

1.       Open a command prompt as an administrator. To open a command prompt as an administrator, click Start. In Start Search, type Command Prompt. At the top of the Start menu, right-click Command Prompt, and then click Run as administrator. If the User Account Control dialog box appears, confirm that the action it displays is what you want, and then click Continue.

2.       At the command prompt, type
w32tm /config /syncfromflags:manual /manualpeerlist:<name of the DC>

3.       At the command prompt, type
w32tm /config /update

Jetzt habe ich im Event-Log des Clients den folgenden Eintrag:
Ereignis-ID: 35
Quelle: Time-Service
Der Zeitdienst synchronisiert die Systemzeit mit folgender Zeitquelle: <name of the DC> (ntp.m|0x0|0.0.0.0:123-><IP of the DC>:123).

Ich werde es weiter verfolgen. Im Moment weicht die Zeit des Clients noch ca. 9 Sekunden von der des Servers ab. Aber der Befehl „w32tm /query /status“ bestätigt, dass die Zeit erfolgreich synchronisiert wird. (Für die Command-Line-Options von w32tm siehe diesen TechNet-Artikel.)